Top-quality features!

  • Controlled steam release after sterilization to avoid overboiling of the liquid products.
  • Programmable start time.
  • Warming function to a presetable temperature of 25 – 80 °C after sterilization.
  • Autofill for demineralised water.
  • Special cleaning programme.
  • Waste program with pulsed heat up for waste sterilization in waste bags to optimise air removal out of waste bags.
  • Process control via state-of-the-art microprocessor technology
  • 6 individual programs standard
  • LCD display for pressure, temperature, time and errors
  • Sterilization parameters – Temperature and time are freely selectable; temperature can be set between 60 and 138 °C. Sterilizing time can be set from 1– 99 minutes. Preselected parameters remain programmed until altered.
  • Sterilization initiation - A PT 100 temperature sensor in a reference vessel guarantees that the set sterilization temperature is actually attained before sterilization starts.
  • RS 232 Interface– For connection to an external computer
  • Demineralised water level regulation– Feed water for steam generation is automatically regulated.
  • Exhaust steam condensation– Exhaust steam is cooled down before leaving the autoclave. No unnecessary steam is exhausted. Drainage equipment protected from contact with steam.
  • Heat-resistant plastic covering on lid– Prevents contact with hot parts and protects from burning.
  • Temperature and pressure regulation– Both parameters are included in the control process, hence guaranteeing an absolutely safe sterilization procedure.
  • Pre-prepared for fitting a printer – Space and electronics are available for the retrospective fitting of a printer for documentation purposes. Fitting is hence easy and inexpensive.
  • Pre-prepared for cooling – The autoclaves are prepared for the retrospective fitting of cooling equipment.
  • Validation port – Ports are available for external temperature sensors for validation and qualification purposes.

Safety first! The safety aspects:

  • Pressure-dependent door lock – Prevents the door from being opened whilst under pressure.
  • Temperature-dependent door lock – In conjunction with temperature measurement in a reference vessel, the system prevents the door from being opened until the temperature is below a specified level, hence preventing delayed boiling (as specified by technical regulations for pressure vessels, complies with British- and German Standards).
  • Door lock safety switch – Prevents the sterilization programme from being started if the door is not properly closed.
  • Water level safety device – Prevents the autoclave from being heated up if insufficient water is available for steam generation.
  • Excess temperature safety device – Switches off the heating elements if too high a temperature is attained.
  • Overpressure valve – release of too high pressure.

 


Click to enlarge it


Technical Data: Serial ELV and MLV

Type Chamber Dimensions Dia x Deeep
inch / mm
Chamber Volume in Gallon  (Liter) External Dim
(W x H x D)
inch / mm
Heating Output
in KW
Voltage
50/60 Hz
Prices
3870 ELV 15.00 x 27.17 22.45 25.60 x 37.40 x 19.68 6.00 208
   (380 x 690) (85) (650 x 950 x 500)          
5075 ELV 19.68 x 29.53 29.06 34.65 x 39.76 x 27.56 9.00 208
  (500 x 750) (160) (880 x 1010 x 700)      

  • The 5075 ELV comes with one basket 240 mm X 485 mm
  • You can fit only two baskets
  • Addtional basket cost $468.00

  • Type 3870 ELV 85 Litter chamber. Type 5075 ELV 160 Litter chamber.

    Loading Capacity

    Erlenmeyer Flasks:

    Type (Fluid Ounce) 3870 ELV 5075 ELV
    7500 (250ml) 30 2 x 42
    15000 (500ml) 3 x 7 4 x 14
    30000 (1000ml) 2 x 4 3 x 8
    60000 (2000ml) 2 x 3 2 x 7
    90000 (3000ml) 2 x 2 2 x 4
    150000 (5000ml) 1 3

    Schott-Duran Flasks:

    Type

    Fluid Ounce

    3870 ELV 5075 ELV
    7500 (250ml) 4 x 18 5 x 30
    15000 (500ml) 3 x 11 4 x 22
    30000 (1000ml) 2 x 8 3 x 15
    60000 (2000ml) 2 x 4 2 x 8
    150000 (5000ml) 2 2 x 4
    300000 (10000ml) 1 2

    Cooling System

    It is recommended that you'll add the cooling system.
    Without the cooling system it's 37 minutes longer per cycle.
    Click for Price

    Supplies which you'll need

  • Air Compressor (min 5 bars)
  • Tap Water for Cooling
  • Mineral Free Water (for steam creation)
  • Drain Outlet

  • For assistance call 1-800-801-9934 and ask for Mark, Shlomo, Chuck,
    Irving, Mike, Bert, Marcus, Daphne, Gary, Jasmine.