Consolidated Stills Sterilizers
![]() |
Alfa Medical eMail
|
|
Standard Features
Safety Features
The Steromaster Mark V Microcomputer Controls - 'MC' Models are our most sophisticated control system.
Steromaster Mark II Digital Controls 'PB' Models - have a digital timer, an indicating, controlling and recording thermometer and a push button cycle selector.
Steromaster Controls
Steroflash Controls
Manual Controls do not have a timer or buzzer to indicate a cycle's progress.
Large Bulk Sterilizers:
ExhaustAutomatic Condensate Exhaust mixes cold water with steam as it exits the sterilizer. The control system activates the water inlet valve automatically during exhaust cycle. Manual Condensate Exhaust mixes cold water with steam as it exits. The sterilizer operator must open the water inlet valve during exhaust cycle. Atmosphere Exhaust releases exiting steam to the atmosphere. This patented technology prevents the escape of infectious bacteria from the sterilizer. It can be sized to accommodate any model and it may also be retrofitted to your existing sterilizer. MountingCabinet mounting for freestanding sterilizers is stainless steel casing fitted over the sterilizer frame. Recess panel mounting for sterilizers mounted into a wall opening consists of stainless steel trim strips to fit over edges of the wall cut-out. Double DoorsDouble door, or pass-through sterilizers are for clean room/dirty room facilities and are available with the accessories below: Cross Contamination Bioseal on the recess end of the sterilizer prevents bacteria migration and maintains the integrity of your clean room. Electric Door Interlock prevents both doors from being opened at the same time. The operator must open either door with a key. Mounting Combinations are stainless steel, recess panel mounting on dirty and clean side or stainless steel, recess panel mounting on one side and stainless steel cabinet on other side. Vacuum OperationVacuum operation is available with Steromaster Mark V Microprocessor Controls only. Choose vacuum operation if:
A vacuum system draws air from the chamber to allow steam to more effectively penetrate packs, bedding and other hard-to-penetrate items. Choose from three vacuum cycles: pre-vacuum, pulse-vacuum and post-vacuum. Other AccessoriesASME Code Stamping is the inspection and authorization stamp of the American Society of Mechanical Engineers, which is required by law in most of the U.S. for pressure vessels and electric steam generators. Loading cart and transfer carriage is a wheel-mounted cart that holds items to be sterilized. The loading cart rolls from the transfer carriage onto the interior chamber tracks for easier handling of heavy loads. Automatic feed water pump boosts feed water pressure for water fed to the boiler if you do not have minimum pressure of 45 PSIG. Automatic jacket blowdown brings jacket and chamber pressure down at the same time to prevent liquids from boiling over and to prevent media from burning. All stainless steel construction is available for the jacket, chamber, or all wetted parts of the sterilizer for tissue culture purposes. Automatic generator blowdown flushes water from steam generator to prevent impurities from building up and minimizes maintenance. 1400 F Cooling valve for facilities that must meet strict regulatory guidelines, cools condensate (hot water exiting the sterilizer) to 140 F. Low temperature controls are available for sterilization between 172 F and 211 F (78 - 100 C). |
![]() |
Alfa Medical eMail
59 Madison Ave, Hempstead, NY 11550 1-800-748-1259 fax 516-489-9364 |
Back To Home Page |
| Dentists and Hand Pieces | Be on Alfa's e-Mail List |